Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Talanta ; 252: 123786, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36027616

RESUMO

In the search for a normalized procedure to replicate and compare single cell-inductively coupled plasma-mass spectrometry (SC-ICP-MS) experiments, SELM-1, a certified reference material containing selenium enriched yeast cells has been used. Selenium concentrations (both, intra- and extracellular) have been measured using either sequential or simultaneous procedures. Regarding quantitative results, the sequential procedure involving cell washing followed by freeze drying of the washed material and intracellular Se quantification using SC-ICP-MS provided best results. In this case, intracellular Se accounted for 1304 ± 48 mg kg-1 (corresponding to 64% of the certified Se content). The average mass of Se per yeast cell was 41.6 fg Se with a dispersion of 1.6-279 fg Se/cell. In the isolated extracellular Se fraction, the Se concentration accounted for 412 ± 48 mg kg-1 (about 21% of the total Se). Thus, the sequential procedure provided a total Se recovery of about 85% with respect to the certified value. The direct dilution and simultaneous measurement of intra- and extracellular Se by SC-ICP-MS provided results of 1024 ± 42 mg kg-1 for intracellular and 316 ± 30 mg kg-1 for extracellular Se representing a total recovery of about 66%. In both cases, an initial thorough characterization of the cell density per solid weighed material was conducted by flow cytometry and the cell integrity ensured using confocal microscopy. These results clearly demonstrated that with appropriate sample preparation, SC-ICP-MS is a unique tool, which is capable of providing quantitative information about intracellular and extracellular Se. In addition, SELM-1 seems the ideal tool to enable data normalization at the single cell level to replicate, benchmark, and improve new SC-ICP-MS studies by using the same material for data validation.


Assuntos
Saccharomyces cerevisiae , Selênio , Saccharomyces cerevisiae/química , Selênio/análise , Espectrometria de Massas/métodos , Análise Espectral , Técnicas de Diluição do Indicador
2.
Anal Methods ; 14(12): 1285-1290, 2022 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-35262123

RESUMO

The increasing demand for the elemental determination of petrochemical samples by inductively coupled plasma techniques requires the development of suitable sample preparation methods that permit high sample throughput and are in accordance with green chemistry recommendations. For this aim, the development of microwave-induced combustion (MIC) method has been attempted to completely digest petroleum coke samples and address quantitative determination of elements, such as Ag, Al, Ba, Ca, Cd, Co, Cu, Fe, Mg, Mn, Mo, Na, Ni, Pb, Sr, V and Zn, by inductively coupled plasma optical emission spectrometry (ICP OES). A sequential procedure to evaluate the sample mass and the solution to retain the analytes quantitatively was first conducted. Satisfactory results were obtained (residual carbon content in final solutions was lower than 0.5%) by digesting 400 mg of samples using 20 bar of oxygen and analytes were quantitatively retained in a dilute acid solution such as 4.2 mol L-1 HNO3. An agreement better than 87% was achieved using certified reference materials and the performance of the proposed method was also compared to that of the standard procedure recommended by the American Society of Testing and Materials ASTM D 5600. Despite both methods producing similar results, the proposed method by MIC was much simpler, offered a higher sample throughput and the digests were compatible with ICP OES measurements avoiding interferences in the determination step compared the ASTM D 5600 method. These results clearly demonstrated that the proposed MIC method in combination with ICP OES could be a promising alternative to obtain quantitative information about the elemental composition of petroleum coke.


Assuntos
Coque , Petróleo , Digestão , Espectrometria de Massas/métodos , Micro-Ondas
3.
Anal Chim Acta ; 1010: 29-36, 2018 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-29447668

RESUMO

A simple and automated system based on combustion followed by a pyrohydrolysis reaction was proposed for further halogens determination. This system was applied for digestion of soils containing high (90%) and also low (10%) organic matter content for further halogens determination. The following parameters were evaluated: sample mass, use of microcrystalline cellulose and heating time. For analytes absorption, a diluted alkaline solution (6 mL of 25 mmol L-1 NH4OH) was used in all experiments. Up to 400 mg of soil with high organic matter content and 100 mg of soil with low organic matter content (mixed with 400 mg of cellulose) could be completely digested using the proposed system. Quantitative results for all halogens were obtained using less than 12 min of sample preparation step (about 1.8 min for sample combustion and 10 min for pyrohydrolysis). The accuracy was evaluated using a certified reference material of coal and spiked samples. No statistical difference was observed between the certified values and results obtained by the proposed method. Additionally, the recoveries obtained using spiked samples were in the range of 98-103% with relative standard deviation values lower than 5%. The limits of quantification obtained for F, Cl, Br and I for soil with high (400 mg of soil) and low (100 mg of soil) organic matter were in the range of 0.01-2 µg g-1 and 0.07-59 µg g-1, respectively. The proposed system was considered as a simple and suitable alternative for soils digestion for further halogens determination by ion chromatography and inductively coupled plasma mass spectrometry techniques.

4.
Anal Chem ; 89(1): 980-987, 2017 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-27958696

RESUMO

A method for digestion of soils with high inorganic matter content (ranging from 50 to 92%) by microwave-induced combustion (MIC) is proposed for the first time for further halogens (F, Cl, Br, and I) determination by ion chromatography (IC) and also by inductively coupled plasma mass spectrometry (ICP-MS). Microcrystalline cellulose (100-500 mg), used as a combustion aid, was mixed with sample and water or NH4OH solutions (10-100 mmol L-1) were investigated for analytes absorption. The use of cellulose (400 mg) was mandatory to volatilize the halogens from soils with high inorganic matter. It was possible to use diluted absorbing solutions (up to 100 mmol L-1 NH4OH) for halogens retention, providing limits of quantification in the range of 0.06 (I) to 60 (Cl) µg g-1. Accuracy was evaluated using certified reference materials (CRMs), spiked samples, and pyrohydrolysis method. Recoveries for halogens after spiked samples were in the range of 94 to 103% and the results after digestion of CRMs by MIC were in agreement better than 95% to certified values. Blanks were low, relative standard deviation was below 8% for all soils and no statistical difference was observed for results by pyrohydrolysis and MIC methods showing the feasibility of the proposed method for further halogens determination in soil samples.

5.
Anal Chim Acta ; 844: 8-14, 2014 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-25172810

RESUMO

A procedure for light and heavy crude oils digestion by microwave-induced combustion (MIC) is proposed for the first time for further rare earth elements (REE) determination by inductively coupled plasma mass spectrometry (ICP-MS) equipped with an ultrasonic nebulizer (USN). Samples of crude oil (API density of 10.8-23.5, up to 250 mg) were inserted in polycarbonate capsules and combusted using 20 bar of oxygen and 50 µL of 6 mol L(-1) ammonium nitrate as igniter. Nitric acid solutions (1-14.4 mol L(-1)) were evaluated for analyte absorption and a reflux step was applied after combustion (5 min of microwave irradiation at 1400 W) in order to achieve better analyte recoveries. Accuracy was evaluated using a spiked sample and also by comparison of results obtained by microwave-assisted digestion combined to ultraviolet radiation (MW-UV) and by neutron activation analysis (NAA). Using 3 mol L(-1) HNO3, quantitative recoveries (better than 97%) were obtained for all analytes. Blank values were always negligible. Agreement was higher than 96% for La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu and Y by comparison of results with those obtained by MW-UV and by NAA (only for La, Ce, Nd, Sm, and Yb). Residual carbon content in digests using MIC was always below 1%. As an advantage over conventional procedures for crude oil digestion, using MIC, it was possible to use diluted acid as absorbing solution, obtaining better limits of detection and avoiding interferences in REE determination by USN-ICP-MS.

6.
Anal Chem ; 85(22): 11034-40, 2013 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-24134679

RESUMO

A method for heavy and extraheavy crude oil digestion based on microwave-assisted wet digestion (MW-AD) and ultraviolet (UV) radiation using diluted HNO3 was applied for the determination of rare earth elements (REE) by inductively coupled plasma mass spectrometry (ICPMS) with an ultrasonic nebulizer (USN). Even using pressurized systems conventional acid digestion is not feasible for efficient crude oil digestion, especially for heavy and extraheavy crude oils that generally present high amounts of asphaltenes and resins. In the proposed system, UV radiation is generated in situ by immersed electrodeless Cd discharge lamps positioned inside quartz vessels. The use of diluted solutions (1-14.4 mol L(-1) HNO3 and 1-4 mol L(-1) H2O2) were evaluated for heavy and extraheavy crude oil digestion (API density of 11.1-19.0). With the proposed method the residual carbon content was lower than 13 mg C/100 mg of sample, and it was possible to digest sample masses up to 500 mg using 4 mol L(-1) HNO3 and 4 mol L(-1) H2O2. Interferences caused by excessive acid concentration and carbon content in digests were minimized allowing limits of quantification for REEs as low as 0.3 ng g(-1). Samples were also digested using MW-AD in pressurized systems with concentrated HNO3, but even using 280 °C, 80 bar, and concentrated HNO3, MW-AD method was not suitable for REE determination due to interferences in ICPMS determination. The combination of microwave heating with UV was considered a suitable and effective way to digest crude oil allowing further determination of low concentrations of REE by ICPMS.

7.
Talanta ; 94: 308-14, 2012 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-22608453

RESUMO

The advantages and shortcomings of focused microwave-induced combustion (FMIC) for digestion of plant samples were studied. The effects of sample mass, absorbing solution, oxygen gas flow-rate, and time of reflux step on recoveries of major, minor and trace metals were systematically evaluated. Afterwards, Al, Ba, Ca, Co, Cr, Cu, Mg, Mn, Ni, Sr, V, and Zn were determined by inductively coupled plasma optical emission spectrometry (ICP OES) and by inductively coupled plasma mass spectrometry (ICP-MS). The main advantages of FMIC when compared to microwave-assisted wet digestion (MAWD) and focused-microwave-assisted wet digestion (FMAWD) are the possibility to digest larger masses of samples (up to 3g) using shorter heating times and diluted nitric acid solution for absorbing all analytes. Using the selected experimental conditions for FMIC, residual carbon content was lower than 0.7% for all samples and relative standard deviation (RSD) varied from 1.5 to 14.1%. Certified reference materials (NIST 1515 apple leaves and NIST 1547 peach leaves) were used for checking accuracy and determined values for all metals were in agreement with certified values at a 95% confidence level. No statistical difference (ANOVA, 95% of confidence level) was observed for results obtained by FMIC, FMAWD, and MAWD. Limits of detection were lower when using FMIC in the range of 0.02-0.15 µg g(-1) for ICP OES and 0.001-0.01 µg g(-1) for ICP-MS, which were about 3 and 6 times lower than the values obtained by FMAWD and MAWD, respectively. It is important to point out that FMIC was a suitable sample preparation method for major, minor and trace metals by both determination techniques (ICP OES and ICP-MS). Additionally, since it allows lower LODs (because up to 3g of sample can be digested) and diluted acid solutions are used (without any further dilution), the use of ICP-MS is not mandatory.


Assuntos
Metais/análise , Plantas/química , Carbono/química , Temperatura Alta , Limite de Detecção , Espectrometria de Massas , Micro-Ondas , Ácido Nítrico/química , Oxigênio/química , Espectrofotometria Atômica
8.
Braz J Med Biol Res ; 39(4): 525-31, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16612476

RESUMO

Anti-HBc positivity is a frequent cause of donation rejection at blood banks. Hepatitis B virus (HBV) infection may also occur in HBsAg-negative patients, a situation denoted occult infection. Similarly, very low levels of HBV-DNA have also been found in the sera of patients with chronic hepatitis C virus (HCV) infection, even in the absence of serum HBsAg. Initially we searched for HBV-DNA in serum of 100 blood donors and 50 HCV-infected patients who were HBsAg negative/anti-HBc positive by nested-PCR and by an HBV monitor commercial test for HBV-DNA. Anti-HBs seroconversion rates were measured in 100 blood donors and in 22 patients with chronic HCV infection after HBV vaccination to determine if the HBV vaccination could eliminate an occult HBV infection in these individuals. Occult HBV infection was detected in proportionally fewer blood donors (6/100 = 6%) than chronic hepatitis C patients (12/50 = 24%) (P < 0.05). We noted seroconversion in 6/6 (100%) HBV-DNA(+) and in 84/94 (89.4%) HBV-DNA(-) blood donors (P > 0.05). All subjects who were HBV-DNA(+) before the first dose of HBV vaccine (D1), became HBV-DNA(-) after D1, D2, and D3. Among 22 HCV-positive patients, 10 HBV-DNA(+) and 12 HBV-DNA(-), seroconversion was observed in 9/10 (90%) HBV-DNA(+) and in 9/12 (75%) HBV-DNA(-) subjects (P > 0.05). The disappearance of HBV-DNA in the majority of vaccinated patients suggests that residual HBV can be eliminated in patients with occult infection.


Assuntos
DNA Viral/sangue , Vacinas contra Hepatite B/imunologia , Vírus da Hepatite B/imunologia , Hepatite B/complicações , Hepatite C Crônica/complicações , Adulto , Idoso , Doadores de Sangue , DNA Viral/imunologia , Feminino , Hepacivirus/imunologia , Hepatite B/imunologia , Anticorpos Anti-Hepatite B/sangue , Antígenos do Núcleo do Vírus da Hepatite B/sangue , Vírus da Hepatite B/genética , Anticorpos Anti-Hepatite C/sangue , Hepatite C Crônica/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase
9.
Braz. j. med. biol. res ; 39(4): 525-531, Apr. 2006. ilus, tab
Artigo em Inglês | LILACS | ID: lil-425084

RESUMO

Anti-HBc positivity is a frequent cause of donation rejection at blood banks. Hepatitis B virus (HBV) infection may also occur in HBsAg-negative patients, a situation denoted occult infection. Similarly, very low levels of HBV-DNA have also been found in the sera of patients with chronic hepatitis C virus (HCV) infection, even in the absence of serum HBsAg. Initially we searched for HBV-DNA in serum of 100 blood donors and 50 HCV-infected patients who were HBsAg negative/anti-HBc positive by nested-PCR and by an HBV monitor commercial test for HBV-DNA. Anti-HBs seroconversion rates were measured in 100 blood donors and in 22 patients with chronic HCV infection after HBV vaccination to determine if the HBV vaccination could eliminate an occult HBV infection in these individuals. Occult HBV infection was detected in proportionally fewer blood donors (6/100 = 6 percent) than chronic hepatitis C patients (12/50 = 24 percent) (P < 0.05). We noted seroconversion in 6/6 (100 percent) HBV-DNA(+) and in 84/94 (89.4 percent) HBV-DNA(-) blood donors (P > 0.05). All subjects who were HBV-DNA(+) before the first dose of HBV vaccine (D1), became HBV-DNA(-) after D1, D2, and D3. Among 22 HCV-positive patients, 10 HBV-DNA(+) and 12 HBV-DNA(-), seroconversion was observed in 9/10 (90 percent) HBV-DNA(+) and in 9/12 (75 percent) HBV-DNA(-) subjects (P > 0.05). The disappearance of HBV-DNA in the majority of vaccinated patients suggests that residual HBV can be eliminated in patients with occult infection.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , DNA Viral/sangue , Vacinas contra Hepatite B/imunologia , Vírus da Hepatite B/imunologia , Hepatite B/complicações , Hepatite C Crônica/complicações , Doadores de Sangue , DNA Viral/imunologia , Hepacivirus/imunologia , Anticorpos Anti-Hepatite B/sangue , Antígenos do Núcleo do Vírus da Hepatite B/sangue , Vírus da Hepatite B/genética , Hepatite B/imunologia , Anticorpos Anti-Hepatite C/sangue , Hepatite C Crônica/imunologia , Reação em Cadeia da Polimerase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...